STEREO/HET/SIT Configuration Tracking Form

 

To be filled in by configuration manager:

 

Tracking Number:  00009                             Date Received: 01/28/04

 

 

To be filled in by initiator:

 

Software Type:    Flight Software               Instrument Name:    HET

           

Version Name:  20031230                        Type of Action:   Problem Report (PR)

 

Initiator's Name: Larry Ryan                      Date Initiated:  01/28/04             

 

 

To be filled in by initiator:

 

Description of action(s)/problems(s): 

 

We cannot get both rates (tmode 0) and raw pulse heights (tmode 1) when connected through SEP Central.

 


 

To be filled in by Programmer:

 

Software Version Name:        20040625

                                   

Programmer(s) Name:         Tom Nolan

 

Date Completed:        06/25/04

 


 

Modules/Routines affected:    Added a tmode 3 option/command which allows the generation of telemetry packets for rates and the raw events.  This format is compatible with transmitting the packets in the time slices permitted when connected to SEP Central.  The algortihm replaces some of the packets with ApIds 592 (processed stopping events) and 593 (processed events) with the raw event packet with  ApId 597.

 

 

 

Comments:

 

Back to main page