STEREO/HET/SIT
Configuration Tracking Form
To be filled in by configuration
manager:
Tracking Number: 00017
Date
Received:
07/14/04
To be filled in by initiator:
Software
Type: Flight Software
Instrument Name:
HET
Version
Name: 20040701
Type of Action:
Design Change (DC)
Initiator's
Name:
Tycho von Rosenvinge/Larry Ryan
Date
Initiated: 07/10/04
To be filled in by initiator:
Description of action(s)/problems(s):
Crosstalk is occuring
between the H1 inner and H1 outer dectectors which is causing events to
be considered as invalid and not processed in the original
algorithm. The algortihm needs to be changed to
determine this crosstalk condition and to discard either the H1 inner
or H1 outer in order to be able to determine the type of event and to
continue with processing.
To be filled in by Programmer:
Software
Version
Name:
20041229 (Build 2)
Programmer(s)
Name: K. Wortman
Date
Completed:
12/20/05
<>
>
<>
Modules/Routines
affected: proc.p24
><>
>
<>Comments: A new Queue_Event routine (phproc.p24)
was designed to determine and cleanuup the crosstalk condition in the
H1 inner and the H1 outer detectors.
>