STEREO/HET/SIT Configuration Tracking Form

 

To be filled in by configuration manager:

 

Tracking Number:  00012                      Date Received: 02/22/04

 

 

To be filled in by initiator:

 

Software Type:    Flight Software               Instrument Name:    HET

           

Version Name:  20031230                        Type of Action:   Design Change (DC)

 

Initiator's Name: Tycho von Rosenvinge     Date Initiated:  02/22/04

 

 

To be filled in by initiator:

 

Description of action(s)/problems(s): 

 

Change the algorithm to access overlaid/combined software counter and particle type tables for the stopping events.  
Change the algorithm to include the 256 x 128 software and particle type tables.


 

To be filled in by Programmer:

 

Software Version Name:         20040701

                                   

Programmer(s) Name:         Tom Nolan

 

Date Completed:        07/01/04

 


Modules/Routines affected:    start.p24

 

 

Comments:   Tables are now overlaid according to the compression type provided in the table file.

 